5V: Cabling dual CN4093 10 Gb converged scalable switches and a Storwize V7000 (single chassis)

Locate and identify the hardware components, cable part numbers, power distribution unit (PDU) part number, and port-to-port cabling sequence in a dual CN4093 10 Gb converged scalable switches and in a Storwize V7000 (Lenovo Converged System single-chassis configuration). This configuration is also known as configuration 5V.

The following indexed diagrams help you map a hardware component to its position on the unit and understand port-to-port cabling sequence between the components. Use these diagrams with the tables that follow.
Note: To locate and identify the hardware components, types of ports, and port numbers in an Lenovo Converged System, see Identifying hardware components in a Lenovo Converged System.
Figure 1. CN4093 10 Gb converged scalable switch cabling for Storwize V7000 control enclosures
CN4093 10 Gb converged scalable switch cabling
Table 1. CN4093 10 Gb converged scalable switch cabling details
Index From: (U-Loc) Port type (bandwidth) Cable type Cable part number Index To: (U-Loc) Port type (bandwidth)
1 Flex System Chassis Management Module (CMM) 1, chassis 1 (U2) RJ-45 (1 Gbps) Cat5e Use the proper cable A To customer network
2 CMM 2, chassis 1 (U2) RJ-45 (1 Gbps) Cat5e Use the proper cable A To customer network
Storwize V7000 control enclosure 1
3 Port 1 in canister 1 or controller A in Storwize V7000 control enclosure (U18) Fibre Channel (8 Gbps) 1 m (3.2 ft) or 1.5 m (4.9 ft) Fibre Channel cable Check the cable label to determine the part number. 4 Port 13 in 10 Gb converged scalable switch, chassis 1, bay 1 (U2) Small form-factor pluggable (SFP)+ (8 Gbps)
5 Port 2 in canister 1 or controller A in Storwize V7000 control enclosure (U18) Fibre Channel (8 Gbps) 6 Port 13 in 10 Gb converged scalable switch, chassis 1, bay 2 (U2) SFP+ (8 Gbps)
7 Port 2 in canister 2 or controller B in Storwize V7000 control enclosure (U18) Fibre Channel (8 Gbps) 8 Port 14 in 10 Gb converged scalable switch, chassis 1, bay 2 (U2) SFP+ (8 Gbps)
9 Port 1 in canister 2 or controller B in Storwize V7000 control enclosure (U18) Fibre Channel (8 Gbps) 10 Port 14 in 10 Gb converged scalable switch, chassis 1, bay 1 (U2) SFP+ (8 Gbps)
Storwize V7000 control enclosure 2
11 Port 1 in canister 1 or controller A in Storwize V7000 control enclosure (U18) Fibre Channel (8 Gbps) 1 m (3.2 ft) or 1.5 m (4.9 ft) Fibre Channel cable Check the cable label to determine the part number. 12 Port 15 in 10 Gb converged scalable switch, chassis 1, bay 1 (U2) SFP+ (8 Gbps)
13 Port 2 in canister 1 or controller A in Storwize V7000 control enclosure (U18) Fibre Channel (8 Gbps) 14 Port 15 in 10 Gb converged scalable switch, chassis 1, bay 2 (U2) SFP+ (8 Gbps)
15 Port 2 in canister 2 or controller B in Storwize V7000 control enclosure (U18) Fibre Channel (8 Gbps) 16 Port 16 in 10 Gb converged scalable switch, chassis 1, bay 2 (U2) SFP+ (8 Gbps)
17 Port 1 in canister 2 or controller B in Storwize V7000 control enclosure (U18) Fibre Channel (8 Gbps) 18 Port 16 in 10 Gb converged scalable switch, chassis 1, bay 1 (U2) SFP+ (8 Gbps)
CN4093 10 Gb converged scalable switch
19 Management port in 10 Gb converged scalable switch, chassis 1, bay 1 (U2) RJ-45 (1 Gbps) 1.5 m (4.9 ft) blue Cat5e 40K8967 20 Management port in 10 Gb converged scalable switch, chassis 1, bay 2 (U2) RJ-45 (1 Gbps)
21 Port 7 in 10 Gb converged scalable switch, chassis 1, bay 1 (U2) Quad small form-factor pluggable (QSFP)+ (40 Gbps) 1 m (3.2 ft) QSFP+ to QSFP+ 49Y7934 22 Port 7 in 10 Gb converged scalable switch, chassis 1, bay 2 (U2) QSFP+ (40 Gbps)
23 Port 1 in 10 Gb converged scalable switch, chassis 1, bay 1 (U2) SFP+ (1 Gbps) Cat5e Use the proper cable A To customer network
24 Port 1 in 10 Gb converged scalable switch, chassis 1, bay 2 (U2) SFP+ (1 Gbps) Cat5e Use the proper cable A To customer network
Figure 2. 32 A single-phase power distribution unit (PDU) cabling
32 A single-phase PDU cabling
Table 2. 32 A single-phase PDU cabling details
Index From Connector type Cable type Cable part number Index To Connector type
PDU part number: 42R8744 (North America only), 42R8743 (worldwide)
1 Outlet 6 in PDU 1 (front) C19 16 A, 100-240 V power cord Check the power cord label to determine the part number. 2 Power supply module, bay 4 C20
3 Outlet 6 in PDU 2 (front) C19 16 A, 100-240 V power cord 4 Power supply module, bay 1 C20
5 Outlet 1A in PDU 1 (rear) C13 10 A, 200-240 V power cord 6 Canister 1 in Storwize V7000 controller (rear) C14
7 Outlet 1A in PDU 2 (rear) C13 10 A, 200-240 V power cord 8 Canister 2 in Storwize V7000 controller (rear) C14
9 Outlet 4 in PDU 1 (front) C19 16 A, 100-240 V power cord 10 Power supply module, bay 5 C20
11 Outlet 4 in PDU 2 (front) C19 16 A, 100-240 V power cord 12 Power supply module, bay 2 C20
13 Outlet 6 in PDU 3 (front) C19 16 A, 100-240 V power cord 14 Power supply module, bay 3 C20
15 Outlet 6 in PDU 4 (front) C19 16 A, 100-240 V power cord 16 Power supply module, bay 6 C20
Figure 3. 32 A three-phase PDU cabling
32 A three-phase PDU cabling
Table 3. 32 A three-phase PDU cabling details
Index From Connector type Cable type Cable part number Index To Connector type
PDU part number: 42R8744 (North America only), 42R8743 (worldwide)
1 Outlet 6 in PDU 1 (front) C19 16 A, 100-240 V power cord Check the power cord label to determine the part number. 2 Power supply module, bay 4 C20
3 Outlet 6 in PDU 2 (front) C19 16 A, 100-240 V power cord 4 Power supply module, bay 1 C20
5 Outlet 1A in PDU 1 (rear) C13 10 A, 200-240 V power cord 6 Canister 1 in Storwize V7000 controller (rear) C14
7 Outlet 1A in PDU 2 (rear) C13 10 A, 200-240 V power cord 8 Canister 2 in Storwize V7000 controller (rear) C14
9 Outlet 4 in PDU 1 (front) C19 16 A, 100-240 V power cord 10 Power supply module, bay 5 C20
11 Outlet 4 in PDU 2 (front) C19 16 A, 100-240 V power cord 12 Power supply module, bay 2 C20
13 Outlet 2 in PDU 2 (front) C19 16 A, 100-240 V power cord 14 Power supply module, bay 3 C20
15 Outlet 2 in PDU 1 (front) C19 16 A, 100-240 V power cord 16 Power supply module, bay 6 C20