80070202-1902ffff
Sensor SEN Vol Fault has transitioned to critical from a less severe state.

Explanation

A failure has been detected in the SEN planar board.

May also be shown as 800702021902ffff or 0x800702021902ffff

Severity

Error

Alert Category

Critical - Voltage

Serviceable

Yes

CIM Information

Prefix: PLAT and ID: 0522

SNMP Trap ID

1

Automatically notify Support

No

User response

Complete the following steps:
  1. Remove any recently installed components.
  2. Try to power on the compute node.
    • If the compute node successfully powers on, complete the following steps:
      1. Check the ServerProven website to make sure that recently installed components are compatible with the compute node.
      2. Inspect the previously installed components for physical damage.
    • If the compute node does not successfully power on or if this is not the first occurrence of this problem, replace the system board.