Use these instructions to install a replacement flash power
module in the storage expansion node.
To install a flash power module, complete the following
steps.
Attention: Make
sure that the drive drawer is supported when it is open. The weight
of installed drives can cause the storage expansion node assembly
to be unstable when the drive drawer is open.
- With the drive drawer open approximately 15 cm (6 in.),
press down slightly on the release on the outer edge of the blue flash
power module bracket and insert the flash power module into the bracket,
with the cable oriented toward the outside of the drive drawer, as
shown in the following illustration.
- Connect the flash power module to the connector on the
underside of the drawer. The connectors are keyed to prevent incorrect
insertion.
- Route the cable through the cable clamps on the underside
of the drawer and close the cable clamps.
After you install the flash power module, complete the
following steps:
- Close the drive drawer.
- Install the cover on the storage expansion node (see Installing the cover on the storage expansion node for instructions).
- Install the storage expansion node assembly
into the chassis (see Installing the storage expansion node in an Flex System Enterprise Chassis for
instructions).