Use these instructions to install a replacement rear bulkhead
on the storage expansion node.
To install the rear bulkhead, complete the following
steps:
- Place the bulkhead so that the screw holes on the bulkhead
are aligned with the screw holes on the storage expansion node.
- Using a T8 Torx screwdriver, install the five screws that
secure the bulkhead, as shown in the following illustration. Use the
screws that you removed when you removed the bulkhead.
- Install the cover on the storage expansion node (see Installing the cover on the storage expansion node for instructions).
Attention: Bend the interposer cable up and over the storage expansion node to
ensure that the cable and connector are clear of the compute node.
- With the left edge of the storage expansion node aligned
with the expansion node alignment mark on the expansion shelf, orient
the slots on the bottom of the storage expansion node with
the posts on the right side of the expansion shelf. Then, slide the storage expansion node toward
the center of the shelf until the retention latch clicks into place,
as shown in the following illustration.
- Connect the interposer cable to the interposer connector
on the compute node system board, as shown in the following illustration.
- If you removed any I/O expansion adapters from the compute
node, install them (see the compute node Installation and Service
Guide for instructions).
- Install the compute node cover (see the compute node Installation
and Service Guide for instructions).
After you install the rear bulkhead, install the storage expansion node assembly
into the chassis. See Installing the storage expansion node in an Flex System Enterprise Chassis for
instructions.