The example configuration 7V consists of an IBMStorwize V7000 Control enclosure, dual Flex System EN4093R 10 Gb Ethernet Scalable Switches and dual FC5022 16 Gb SAN Fibre Channel Scalable Switches. This configuration is also known as configuration 7V.
Index letter | Machine type, model, or feature code | Description | Quantity |
---|---|---|---|
A | 8731-AC1 | Flex System Manager | 1 |
B | x220 Type 7906, x222 Type 7916, x240 Type 8737, x240 M5 Type 9532, x440 Type 7167, x480 or x880 Type 7903 | Compute nodes | Minimum 1 per chassis, then add until node bays are full |
C | 8721-HC1 | Flex System chassis | 1 |
D | EN4093R | Flex System EN4093R
10 Gb Ethernet Scalable Switch See Table 2 for mezzanine card options. |
2 |
E | - | Node bay fillers | 1 in each unused node bay |
F | 6195-524 | Storwize V7000 Control Enclosure | 0, 1 or 2 |
G | 6195-24F | Storwize V7000 Expansion Enclosure | Optional *. Up to 20. expansion enclosures per control enclosure. |
H | FC5022 | Flex System FC5022
16 Gb SAN Fibre Channel Scalable Switch See Table 2 for mezzanine card options. |
2 |
I | 9363-RC4 | Lenovo Converged System 42U Rack | 0 or 1* |
9363-RC4 | Lenovo Converged System (overflow 42U rack) | Optional** | |
* A Lenovo Converged System 42U rack is mandatory when the Storwize V7000 Control Enclosure is included but can be deleted from systems ordered without rack storage. ** When you add Storwize V7000 Expansion Enclosures to your configuration, a Lenovo Converged System 42U rack will be added to your order when a 2nd (overflow) rack is required. |
Machine type, model, or feature code | Description | Quantity | |
---|---|---|---|
The following mezzanine cards can be ordered with the Flex System EN4093R 10 Gb Ethernet Scalable Switch: | |||
A4K2 | Flex System CN4054 10 Gb Virtual Fabric Adapter. Note: This mezzanine card is used for an LOM-less system board, or when extra NIC ports are needed. These include: x220 (7906-AC1), x240 (8737-AC1), and x440 (7917-AC1). | 1 or 2 | |
The following mezzanine cards can be ordered with the Flex System FC5022 16 Gb SAN Fibre Channel Scalable Switch: | |||
A3HU | x222 compute node: Flex System FC5024D 4-port 16 Gb FC Adapter | 1 | |
A45R | Flex System FC 5052 2-port 16 Gb FC Adapter | 1 for x240, x480, and x880 or 2 for x440 | |
A2N5 | x240 and x440 compute nodes: Flex System FC3052 2-port 8 Gb FC Adapter | 1 for x240 or 2 for x440 | |
Note: You can have two mezzanine cards per full
wide compute node. Or, you can have one mezzanine card per half wide
compute node.
|
Feature code | Base | Expansion | Description | Feature code - Service agreement | |
---|---|---|---|---|---|
5641-CBC | X | Storwize V7000 Software, v6.4.0, or later (1) | 5639-SM3 - 1-year base software maintenance agreement (SWMA). Optional 3-year SWMA. | ||
5641-XBC | X | Real-time Compression (RTC) Software, v6.4.0, or later (1) | 5639-XXX - 3-year RTC SWMA | ||
1. See the documentation that comes with the Storwize V7000 storage system for more information. |
Feature code | Base | Expansion | Description | Feature code - Service agreement | |
---|---|---|---|---|---|
5641-F01 | X | Flex System Manager management software Advanced, 1-year Software Maintenance Agreement EB31 (Platform Manager software
bundle indicator) is required with every Flex System Manager, and EB32
(virtualization manager software bundle indicator) requires EB31 in
the same quantities.
|
5641-F02 - 3-year SWMA (optional) |
Feature code | Base | Expansion | Description | Feature code - Service agreement | |
---|---|---|---|---|---|
AB0B | X | ESXi USB Hypervisor Key (VMware version 5, update 1) (for X architecture compute nodes) |
Feature code | Description |
---|---|
Software maintenance (SWMA): | |
3-years, 9 a.m. x 5 p.m. | |
Hardware maintenance (HWMA): | |
3-years, 9 a.m. x 5 p.m., next business day service | |
Maintenance and Technical Support (MTS) offering: | |
3-years with 24x7 same business day | |
3-years with two microcode analysis per year | |
3-years with 24x7 account advocate |