On Power Systems compute nodes, both hardware events and operating system events are detected and sent to the IBM Flex System Manager.
The following diagram shows the flow of events from a Power7 compute node node
to the IBM Flex System Manager:
Log ID Time Failing Subsystem Severity SRC 5011FC2A 2011-07-27 19:40:55 Processor Unit (CPU) Unrecoverable Error, B113E504 Degraded Performance
Log ID Time Failing Subsystem Severity SRC 5011FC84 2011-07-27 19:42:27 Processor Unit (CPU) Unrecoverable Error B113E504
If an IBM Flex System Manager agent is installed on the Power7 compute node, it will send an alert to the CMM from each operating system partition. These alerts will also be posted to the CMM event log.
Event Text Severity System Category Time Received State of the virtual server hstfb19p01 changed to Stopped hstfb19p01 Information Alert July 27, 2011 9:44:40 PM State of the virtual server hstfb19p01 changed to Not Available hstfb19p01 Warning Alert July 27, 2011 9:48:12 PM State of the virtual server hstfb19p01 changed to Started hstfb19p01 Information Alert July 27, 2011 9:52:32 PM
This event is considered to be a call home event. Therefore, if Electronic Service Agent is enabled on the CMM, the event (along with service data) will be automatically sent to the Support team, who will notify you about a resolution to the issue.