The Lenovo Chassis Management Module 2 modules use a variety of TCP/IP ports for communication. This topic lists these ports and indicates the ones that are fixed or can be changed by an administrator. You need to make sure that your network allows communications through these ports for the Lenovo Chassis Management Module 2 modules to function and communicate correctly.
Port name | Port number | Description |
---|---|---|
CIM/XML HTTPS | 5989 (default) | CIM/XML HTTPS used by management applications |
FTP | 21 (default) | FTP |
FTP Data | 20 (default) | FTP Data |
http | 80 (default) | Web server HTTP connection - TCP |
https | 443 (default) | SSL connection for HTTP-TCP |
Secure TCP Command Mode | 6091 (default) | Secure TCP Command Mode used by management applications |
SLP | 427 (default) | Service location protocol - UDP |
SNMP agent | 161 (default) | SNMP get/set commands - UDP |
SNMP traps | 162 (default) | SNMP traps |
SSH | 22 (default) | Secure Shell (SSH) command-line interface - TCP |
TCP Command Mode | 6090 (default) | TCP Command Mode |
telnet | 23 (default) | Telnet command-line interface connection -TCP |
TFTP | 69 (default) | TFTP |
Port number | Description |
---|---|
25 | E-mail alerts - TCP |
53 | DNS resolver - UDP |
67 and 68 | DHCP - UDP |
123 | NTP |
389 | LDAP server port |
547 | DHCP (IPv6) - UDP |
623 | RMCP (Remote Management and Control Protocol) |
636 | LDAPS (secure LDAP) |
830 | NETCONF (Network Configuration Protocol) Note: If
an I/O module supports the NETCONF protocol, port 830 is open by default.
|