This command displays the partition control and configuration settings for multiple compute nodes or nodes in a scalable complex, for compute nodes installed in the Lenovo Flex System chassis that support this feature.
If command syntax is not correctly entered, or if a command fails to run, an error message is returned. See Common errors for a list of error messages that apply to all commands or scale command errors for a list of error messages that are specific to the scale command.
Function | What it does | Command | Target (see paths in Command targets) |
---|---|---|---|
Display all scalable complex information | Displays all scalable complex information for the Lenovo Flex System chassis. | scale | Lenovo Flex System chassis:
|
Display information for specific scalable complex | Displays information for the specified scalable
complex. Note:
|
scale
-compid complex_id where complex_id is a unique complex identifier (hexadecimal string of four alphanumeric characters), assigned by the compute node complex. |
Lenovo Flex System chassis:
|
Display information for specific node in a scalable complex | Displays information for a specific node in the
scalable complex. Note:
|
scale
-compid complex_id -node node_id where :
|
Lenovo Flex System chassis:
|
Display information for specific partition in a scalable complex | Displays information for a specific partition in
the scalable complex. Note:
|
scale
-compid complex_id -partid partition_id where :
|
Lenovo Flex System chassis:
|
scale
scale -compid D787
scale -compid D787 -partid 1
scale -compid D787 -node 7
The following example shows the information that is returned from these commands:
system> scale --- Complex ID: D787 --- Partition ID: 1 Assigned Nodes: --------------- Bay: 1 Name: Node 01 Processors/Memory: 2 Intel Xeon/2 DIMMs 4GB Logical Node ID: 0 Status: powered off Mode: partition Primary: Yes Bay: 3 Name: Node 03 Processors/Memory: 2 Intel Xeon/2 DIMMs 4GB Logical Node ID: 1 Status: powered on Mode: partition Primary: No Bay: 5 Name: Node 05 Processors/Memory: 2 Intel Xeon/2 DIMMs 4GB Logical Node ID: 2 Status: powered off Mode: partition Primary: No Bay: 7 Name: Node 07 Processors/Memory: 2 Intel Xeon/2 DIMMs 4GB Logical Node ID: 3 Status: powered off Mode: partition Primary: No system> scale -compid D787 Partition ID: 1 Assigned Nodes: --------------- Bay: 1 Name: Node 01 Processors/Memory: 2 Intel Xeon/2 DIMMs 4GB Logical Node ID: 0 Status: powered off Mode: partition Primary: Yes Bay: 3 Name: Node 03 Processors/Memory: 2 Intel Xeon/2 DIMMs 4GB Logical Node ID: 1 Status: powered on Mode: partition Primary: No Bay: 5 Name: Node 05 Processors/Memory: 2 Intel Xeon/2 DIMMs 4GB Logical Node ID: 2 Status: powered off Mode: partition Primary: No Bay: 7 Name: Node 07 Processors/Memory: 2 Intel Xeon/2 DIMMs 4GB Logical Node ID: 3 Status: powered off Mode: partition Primary: No system> scale -compid D787 -partid 1 Partition ID: 1 Assigned Nodes: --------------- Bay: 1 Name: Node 01 Processors/Memory: 2 Intel Xeon/2 DIMMs 4GB Logical Node ID: 0 Status: powered off Mode: partition Primary: Yes Bay: 3 Name: Node 03 Processors/Memory: 2 Intel Xeon/2 DIMMs 4GB Logical Node ID: 1 Status: powered on Mode: partition Primary: No Bay: 5 Name: Node 05 Processors/Memory: 2 Intel Xeon/2 DIMMs 4GB Logical Node ID: 2 Status: powered off Mode: partition Primary: No Bay: 7 Name: Node 07 Processors/Memory: 2 Intel Xeon/2 DIMMs 4GB Logical Node ID: 3 Status: powered off Mode: partition Primary: No system> scale -compid D787 -node 7 UUID: 0C5513A7 25274D0B 931EDEC6 95571364 Serial Number: NANW00R Checksum: 3403 Number of Ports: 3 Ports: ------ Port ID: 0 Remote Checksum: A100 Remote Port ID: 2 Status: Enabled Type: QPI Port ID: 1 Remote Checksum: D401 Remote Port ID: 2 Status: Enabled Type: QPI Port ID: 2 Remote Checksum: 7402 Remote Port ID: 2 Status: Enabled Type: QPI system>