This command displays and configures alerts that are monitored by the CMM.
If command syntax is not correctly entered, or if a command fails to run, an error message is returned. See Common errors for a list of error messages that apply to all commands or monalerts command errors for a list of error messages that are specific to the monalerts command.
Function | What it does | Command | Target (see paths in Command targets) |
---|---|---|---|
Display monitored alert states | Displays the state of all alerts being monitored by the CMM. | monalerts | Primary CMM:
|
Set state for enhanced legacy alert categories | Enables enhanced legacy alert categories.
|
monalerts
-ec state where state is enabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for all critical alerts | Enables or disables monitoring of all critical alerts. | monalerts
-ca state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for node device critical alerts | Enables or disables monitoring of node device critical alerts. | monalerts
-cb state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for I/O-module critical alerts | Enables or disables monitoring of I/O-module critical alerts. | monalerts
-ciom state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for chassis or system management critical alerts | Enables or disables monitoring of chassis or system management critical alerts. | monalerts
-ccsm state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for cooling device critical alerts | Enables or disables monitoring of cooling device critical alerts. | monalerts
-ccd state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for power supply critical alerts | Enables or disables monitoring of power supply critical alerts. | monalerts
-cpm state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for all warning alerts | Enables or disables monitoring of all warning alerts. Note: When installed in a Lenovo Flex System Carrier-Grade chassis,
this command option sets the monitoring state for major and minor
events.
|
monalerts
-wa state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for node device warning alerts | Enables or disables monitoring of node device warning
alerts. Note: When installed in a Lenovo Flex System Carrier-Grade
chassis, this command option sets the monitoring state for major and
minor events.
|
monalerts
-wb state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for I/O-module warning alerts | Enables or disables monitoring of I/O-module warning
alerts. Note: When installed in a Lenovo Flex System Carrier-Grade
chassis, this command option sets the monitoring state for major and
minor events.
|
monalerts
-wiom state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for chassis or system management warning alerts | Enables or disables monitoring of chassis or system
management warning alerts. Note: When installed in a Lenovo
Flex System Carrier-Grade chassis, this command option sets the monitoring
state for major and minor events.
|
monalerts
-wcsm state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for event log warning alerts | Enables or disables monitoring of event log warning
alerts. Note: When installed in a Lenovo Flex System Carrier-Grade
chassis, this command option sets the monitoring state for major and
minor events.
|
monalerts
-wel state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for cooling device warning alerts | Enables or disables monitoring of cooling device
warning alerts. Note: When installed in a Lenovo Flex System
Carrier-Grade chassis, this command option sets the monitoring state
for major and minor events.
|
monalerts
-wcd state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for power supply warning alerts | Enables or disables monitoring of power supply
warning alerts. Note: When installed in a Lenovo Flex System
Carrier-Grade chassis, this command option sets the monitoring state
for major and minor events.
|
monalerts
-wpm state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for all informational alerts | Enables or disables monitoring of all informational alerts. | monalerts
-ia state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for node device informational alerts | Enables or disables monitoring of node device informational alerts. | monalerts
-ib state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for I/O-module informational alerts | Enables or disables monitoring of I/O-module informational alerts. | monalerts
-iiom state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for chassis or system management informational alerts | Enables or disables monitoring of chassis or system management informational alerts. | monalerts
-icsm state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for power state informational alerts | Enables or disables monitoring of power state (on/off) informational alerts. | monalerts
-ipon state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for inventory change informational alerts | Enables or disables monitoring of inventory change (installed components) informational alerts. | monalerts
-iinv state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for event log informational alerts | Enables or disables monitoring of event log informational alerts. | monalerts
-iel state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for network change informational alerts | Enables or disables monitoring of network change informational alerts. | monalerts
-inc state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for user activity informational alerts | Enables or disables monitoring of user activity informational alerts. | monalerts
-iua state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for cooling device informational alerts | Enables or disables monitoring of cooling device informational alerts. | monalerts
-icd state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
Set monitoring state for power supply informational alerts | Enables or disables monitoring of power supply informational alerts. | monalerts
-ipm state where state is enabled or disabled . This
command can only be run by users who have one or more of the following
command authorities:
|
Primary CMM:
|
monalerts -ca enabled -wel enabled -ia disabled -T mm[p]
The following example shows the information that is returned from this command:
system> monalerts -ca enabled -wel enabled -ia disabled -T mm[p] OK system>