This command displays and sets the LED states for a specified command target, if this command target supports the LED.
If command syntax is not correctly entered, or if a command fails to run, an error message is returned. See Common errors for a list of error messages that apply to all commands or led command errors for a list of error messages that are specific to the led command.
Function | What it does | Command | Target (see paths in Command targets) |
---|---|---|---|
Display LED states for chassis | Displays various LED states for the chassis. | led | Lenovo Flex System
chassis:
|
Display fault LED state for chassis | Displays fault LED state for the chassis. | led | Primary CMM:
|
Display state for compute node LEDs | Displays the state of the compute node LEDs. | led | Compute node:
|
Display state for rear LED card LEDs | Displays the state of the rear LED card LEDs of the Lenovo Flex System chassis. | led | Rear LED card:
|
Display state for fanpack LEDs | Displays the state of the fan pack LEDs of the Lenovo Flex System chassis. | led | Power supply fan pack:
|
Display state for fan logic module LEDs | Displays the state of the fan logic module LEDs of the Lenovo Flex System chassis. | led | Fan logic module:
|
Display state for fan module fault LED | Displays the state of the fan module fault LED of the Lenovo Flex System chassis. | led | Fan module:
|
Display state for I/O module LEDs | Displays state of the LEDs for the specified I/O module. | led | I/O module:
|
Turn off information LED Note: This command option
applies only to CMMs
installed in a Flex System Enterpise chassis.
|
Turns off the information LED, that is on the Flex System Enterpise chassis and some chassis components, for the specified command target | led -info off This
command can only be run by users who have one or more of the following
command authorities:
|
Lenovo Flex System
chassis:
Compute node:
Rear LED card:
|
Turn off compute node information LED Note: This command
option applies only to CMMs
installed in a Lenovo Flex System Carrier-Grade chassis.
|
Turns off the information LED, that is on the specified compute node target in a Lenovo Flex System Carrier-Grade chassis. | led -info off This
command can only be run by users who have one or more of the following
command authorities:
|
Compute node:
|
Set identify LED state | Sets the state of the identify LED, that is on the Lenovo Flex System chassis and some compute nodes and I/O modules, for the command target. | led
-loc state where state is
Note: A state of blink can
only be used for the system and mt command
targets and for the compute nodes.
This
command can only be run by users who have one or more of the following
command authorities:
|
Lenovo Flex System
chassis:
Rear LED card:
Compute node:
I/O module:
|
Example:To display the LED status for the compute node in bay 2, while the Lenovo Flex System chassis is set as the persistent command environment, at the system> prompt, type
led -T blade[2]
The following example shows the information that is returned from this command:
system> led -T blade[2] Sys Brd off -loc off Fault LED off Power LED blink -info off Mgmt Crd off DIMM 1 off DIMM 4 off DIMM 9 off DIMM 12 off Mezz Crd0 off system>