Use this information to solve undetermined problems.
Any undetermined problem
Complete the following steps until the problem is solved.
- Check the IMM event log and follow the suggested actions to resolve
any event codes (see IMM event log).
- Find the symptoms that you are experiencing in the troubleshooting
tables in this section and follow the suggested actions to resolve
any problems.
- If the problem remains, submit a
service request (see Getting help and technical assistance).
Compute nodes are not discovered by the Flex System Manager management
node or the CMM
Complete the following steps until the problem is solved.
- Make sure that the compute node is recognized by the Flex System Manager management
node (if installed) or the CMM. It may appear as an unknown device
in the chassis map. If it is not recognized, perform the following
steps.
- Remove the compute node and inspect both the compute node and
the back of the compute node bay to ensure there is no physical damage
to connectors.
- Move the compute node to another bay.
- Replace the system-board assembly (see Removing and replacing the system-board assembly).
- Make sure that the Flex System Manager management
node or the CMM can ping the compute nodes, if they cannot, see Cannot ping the Flex System Manager management node on the management network.
- If the compute nodes are in another chassis, make sure that you
have the proper software entitlements to manage that chassis with
the Flex System Manager management
node.
- Check Lenovo Support for
any firmware updates that might apply to this issue. You can view
the release notes for a firmware update to determine the issues that
are addressed by the update.
- Check Lenovo Support for
any service bulletins that are related to network connectivity.