If you omit any optional parameter, the default value is
used.
To update the UUID, in the ASU command-line interface,
enter the following command:
asu set SYSTEM_PROD_DATA.SysInfoUUID uuid --host ipaddress
[--user userid][--password password
where:
-
uuid
- is the user-assigned
hexadecimal value, up to 16 bytes, that identifies the compute node.
-
ipaddress
- is the external
LAN IP address of the IMM2.
-
userid
- is the IMM2 account
name (1 of 12 accounts). The default is USERID.
-
password
- is the IMM2 account
password (1 of 12 accounts). The default is PASSW0RD (with a zero,
not the letter O).
To update the DMI/SMBIOS data, complete the following steps:
-
In the ASU command-line interface, enter the following
command:
asu set SYSTEM_PROD_DATA.SysInfoProdName xxxxyyy --host ipaddress
[--user userid][--password password]
Important: The default machine type and model number in the
system-board firmware might not be the machine type and model number
of the compute node. Make sure that you enter the correct machine
type and model number.
where:
-
xxxx
- is the 4-digit machine
type of the compute node.
-
yyy
- is the 3-digit model
number of the compute node.
-
ipaddress
- is the external
LAN IP address of the IMM2.
-
userid
- is the IMM2 account
name (1 of 12 accounts). The default is USERID.
-
password
- is the IMM2 account
password (1 or 12 accounts). The default is PASSW0RD (with a zero,
not the letter O).
-
Enter the following command:
asu set SYSTEM_PROD_DATA.SysInfoSerialNum zzzzzzz --host ipaddress
[--user userid][--password password]
where zzzzzzz is the 7-character serial number of the
compute node.
-
Enter the following command:
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa --host ipaddress
[--user userid][--password password
where aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is the 33-character
asset tag number of the compute node.
-
Restart the IMM.
-
Restart the server.