201-000-000
:
Standalone Memory Test Passed
Quick/Full Memory Test All CPUs Passed.
- Recoverable
- No
- Severity
- Event
- Serviceable
- No
- Automatically notify support
- No
- Related links
-
201-000-001
:
Standalone Memory Test Passed
Quick/Full Memory Test CPU 1 Passed.
- Recoverable
- No
- Severity
- Event
- Serviceable
- No
- Automatically notify support
- No
- Related links
-
201-000-002
:
Standalone Memory Test Passed
Quick/Full Memory Test CPU 2 Passed.
- Recoverable
- No
- Severity
- Event
- Serviceable
- No
- Automatically notify support
- No
- Related links
-
201-000-003
:
Standalone Memory Test Passed
Quick/Full Memory Test CPU 3 Passed.
- Recoverable
- No
- Severity
- Event
- Serviceable
- No
- Automatically notify support
- No
- Related links
-
201-000-004
:
Standalone Memory Test Passed
Quick/Full Memory Test CPU 4 Passed.
- Recoverable
- No
- Severity
- Event
- Serviceable
- No
- Automatically notify support
- No
- Related links
-
201-811-000
:
Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-811-001
:
Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-811-002
:
Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-811-003
:
Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-812-000
:
Standalone Memory Test Aborted
Memory test is not supported for this system.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-812-001
:
Standalone Memory Test Aborted
Memory test is not supported for this system.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-812-002
:
Standalone Memory Test Aborted
Memory test is not supported for this system.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-812-003
:
Standalone Memory Test Aborted
Memory test is not supported for this system.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-813-000
:
Standalone Memory Test Aborted
Chipset Error: Can not turn OFF ECC error reporting in CPU.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-813-001
:
Standalone Memory Test Aborted
Chipset Error: Can not turn OFF ECC error reporting in CPU.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-813-002
:
Standalone Memory Test Aborted
Chipset Error: Can not turn OFF ECC error reporting in CPU.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-813-003
:
Standalone Memory Test Aborted
Chipset Error: Can not turn OFF ECC error reporting in CPU.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-814-000
:
Standalone Memory Test Aborted
Chipset Error: Can not disable Scubbing feature for CPU.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-814-001
:
Standalone Memory Test Aborted
Chipset Error: Can not disable Scubbing feature for CPU.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-814-002
:
Standalone Memory Test Aborted
Chipset Error: Can not disable Scubbing feature for CPU.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-814-003
:
Standalone Memory Test Aborted
Chipset Error: Can not disable Scubbing feature for CPU.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-815-000
:
Standalone Memory Test Aborted
Program Error with Quick Memory Menu Option Selection.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-815-001
:
Standalone Memory Test Aborted
Program Error with Quick Memory Menu Option Selection.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-815-002
:
Standalone Memory Test Aborted
Program Error with Quick Memory Menu Option Selection.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-815-003
:
Standalone Memory Test Aborted
Program Error with Quick Memory Menu Option Selection.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-816-000
:
Standalone Memory Test Aborted
Program Error with Full Memory Menu Option Selection.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-816-001
:
Standalone Memory Test Aborted
Program Error with Full Memory Menu Option Selection.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-816-002
:
Standalone Memory Test Aborted
Program Error with Full Memory Menu Option Selection.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-816-003
:
Standalone Memory Test Aborted
Program Error with Full Memory Menu Option Selection.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-818-000
:
Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-818-001
:
Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-818-002
:
Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-818-003
:
Standalone Memory Test Aborted
Unable to Locate SMBIOS key "_SM_".
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-819-000
:
Standalone Memory Test Aborted
The start-end address ranges in the restricted area of the memory.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-819-001
:
Standalone Memory Test Aborted
The start-end address ranges in the restricted area of the memory.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-819-002
:
Standalone Memory Test Aborted
The start-end address ranges in the restricted area of the memory.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-819-003
:
Standalone Memory Test Aborted
The start-end address ranges in the restricted area of the memory.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-820-000
:
Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-820-001
:
Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-820-002
:
Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-820-003
:
Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-821-000
:
Standalone Memory Test Aborted
Variable range MTRR registers are larger than fixed range MTRR registers.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-821-001
:
Standalone Memory Test Aborted
Variable range MTRR registers are larger than fixed range MTRR registers.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-821-002
:
Standalone Memory Test Aborted
Variable range MTRR registers are larger than fixed range MTRR registers.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-821-003
:
Standalone Memory Test Aborted
Variable range MTRR registers are larger than fixed range MTRR registers.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-822-000
:
Standalone Memory Test Aborted
Invalid MTRR service request.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-822-001
:
Standalone Memory Test Aborted
Invalid MTRR service request.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-822-002
:
Standalone Memory Test Aborted
Invalid MTRR service request.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-822-003
:
Standalone Memory Test Aborted
Invalid MTRR service request.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-824-000
:
Standalone Memory Test Aborted
Node Interleave feature must be OFF. Go to Setup and disable Node Interleave option and then re-run the test.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-824-001
:
Standalone Memory Test Aborted
Node Interleave feature must be OFF. Go to Setup and disable Node Interleave option and then re-run the test.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-824-002
:
Standalone Memory Test Aborted
Node Interleave feature must be OFF. Go to Setup and disable Node Interleave option and then re-run the test.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-824-003
:
Standalone Memory Test Aborted
Node Interleave feature must be OFF. Go to Setup and disable Node Interleave option and then re-run the test.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-826-000
:
Standalone Memory Test Aborted
BIOS: Memory Controller has been disabled. Go to Setup and Enable Memory Controller.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-826-001
:
Standalone Memory Test Aborted
BIOS: Memory Controller has been disabled. Go to Setup and Enable Memory Controller.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-826-002
:
Standalone Memory Test Aborted
BIOS: Memory Controller has been disabled. Go to Setup and Enable Memory Controller.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-826-003
:
Standalone Memory Test Aborted
BIOS: Memory Controller has been disabled. Go to Setup and Enable Memory Controller.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-827-000
:
Standalone Memory Test Aborted
BIOS: ECC function has been disabled by BIOS. Go to Setup and enable ECC generation.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-827-001
:
Standalone Memory Test Aborted
BIOS: ECC function has been disabled by BIOS. Go to Setup and enable ECC generation.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-827-002
:
Standalone Memory Test Aborted
BIOS: ECC function has been disabled by BIOS. Go to Setup and enable ECC generation.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-827-003
:
Standalone Memory Test Aborted
BIOS: ECC function has been disabled by BIOS. Go to Setup and enable ECC generation.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-844-000
:
Standalone Memory Test Aborted
Chipset Error: Problem in masking MSR machine check control MASK registers.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-844-001
:
Standalone Memory Test Aborted
Chipset Error: Problem in masking MSR machine check control MASK registers.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-844-002
:
Standalone Memory Test Aborted
Chipset Error: Problem in masking MSR machine check control MASK registers.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-844-003
:
Standalone Memory Test Aborted
Chipset Error: Problem in masking MSR machine check control MASK registers.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-845-000
:
Standalone Memory Test Aborted
Chipset Error: Problem clearing MSR machine check control registers.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-845-001
:
Standalone Memory Test Aborted
Chipset Error: Problem clearing MSR machine check control registers.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-845-002
:
Standalone Memory Test Aborted
Chipset Error: Problem clearing MSR machine check control registers.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-845-003
:
Standalone Memory Test Aborted
Chipset Error: Problem clearing MSR machine check control registers.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-859-000
:
Standalone Memory Test Aborted
INVALID XSECSRAT type.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-859-001
:
Standalone Memory Test Aborted
INVALID XSECSRAT type.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-859-002
:
Standalone Memory Test Aborted
INVALID XSECSRAT type.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-859-003
:
Standalone Memory Test Aborted
INVALID XSECSRAT type.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-860-000
:
Standalone Memory Test Aborted
No OEM0 type 1 found.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-860-001
:
Standalone Memory Test Aborted
No OEM0 type 1 found.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-860-002
:
Standalone Memory Test Aborted
No OEM0 type 1 found.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-860-003
:
Standalone Memory Test Aborted
No OEM0 type 1 found.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-861-000
:
Standalone Memory Test Aborted
No SRAT type 1 found.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-861-001
:
Standalone Memory Test Aborted
No SRAT type 1 found.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-861-002
:
Standalone Memory Test Aborted
No SRAT type 1 found.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-861-003
:
Standalone Memory Test Aborted
No SRAT type 1 found.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-862-000
:
Standalone Memory Test Aborted
No OEM1 structure found.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-862-001
:
Standalone Memory Test Aborted
No OEM1 structure found.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-862-002
:
Standalone Memory Test Aborted
No OEM1 structure found.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-862-003
:
Standalone Memory Test Aborted
No OEM1 structure found.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-863-000
:
Standalone Memory Test Aborted
No IBMERROR key in OEM1 structure.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-863-001
:
Standalone Memory Test Aborted
No IBMERROR key in OEM1 structure.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-863-002
:
Standalone Memory Test Aborted
No IBMERROR key in OEM1 structure.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-863-003
:
Standalone Memory Test Aborted
No IBMERROR key in OEM1 structure.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-864-000
:
Standalone Memory Test Aborted
No GAS located in OEM1.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-864-001
:
Standalone Memory Test Aborted
No GAS located in OEM1.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-864-002
:
Standalone Memory Test Aborted
No GAS located in OEM1.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-864-003
:
Standalone Memory Test Aborted
No GAS located in OEM1.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-865-000
:
Standalone Memory Test Aborted
No XSECSRAT key in OEM0 structure.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-865-001
:
Standalone Memory Test Aborted
No XSECSRAT key in OEM0 structure.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-865-002
:
Standalone Memory Test Aborted
No XSECSRAT key in OEM0 structure.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-865-003
:
Standalone Memory Test Aborted
No XSECSRAT key in OEM0 structure.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-866-000
:
Standalone Memory Test Aborted
EFI-SAL Invalid parameter from GetMemoryMap function.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-866-001
:
Standalone Memory Test Aborted
EFI-SAL Invalid parameter from GetMemoryMap function.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-866-002
:
Standalone Memory Test Aborted
EFI-SAL Invalid parameter from GetMemoryMap function.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-866-003
:
Standalone Memory Test Aborted
EFI-SAL Invalid parameter from GetMemoryMap function.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-867-000
:
Standalone Memory Test Aborted
EFI/SAL: Buffer not allocated.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-867-001
:
Standalone Memory Test Aborted
EFI/SAL: Buffer not allocated.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-867-002
:
Standalone Memory Test Aborted
EFI/SAL: Buffer not allocated.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-867-003
:
Standalone Memory Test Aborted
EFI/SAL: Buffer not allocated.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-868-000
:
Standalone Memory Test Aborted
EFI/SAL: Buffer allocated in GetMemoryMap too small.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-868-001
:
Standalone Memory Test Aborted
EFI/SAL: Buffer allocated in GetMemoryMap too small.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-868-002
:
Standalone Memory Test Aborted
EFI/SAL: Buffer allocated in GetMemoryMap too small.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-868-003
:
Standalone Memory Test Aborted
EFI/SAL: Buffer allocated in GetMemoryMap too small.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-869-000
:
Standalone Memory Test Aborted
EFI/SAL Invalid parameter from GetMemoryMap function.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-869-001
:
Standalone Memory Test Aborted
EFI/SAL Invalid parameter from GetMemoryMap function.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-869-002
:
Standalone Memory Test Aborted
EFI/SAL Invalid parameter from GetMemoryMap function.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-869-003
:
Standalone Memory Test Aborted
EFI/SAL Invalid parameter from GetMemoryMap function.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-870-000
:
Standalone Memory Test Aborted
CPU Doamin in ACPI not valid.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-870-001
:
Standalone Memory Test Aborted
CPU Doamin in ACPI not valid.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-870-002
:
Standalone Memory Test Aborted
CPU Doamin in ACPI not valid.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-870-003
:
Standalone Memory Test Aborted
CPU Doamin in ACPI not valid.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-871-000
:
Standalone Memory Test Aborted
Data Mis-compare encountered.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-871-001
:
Standalone Memory Test Aborted
Data Mis-compare encountered.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-871-002
:
Standalone Memory Test Aborted
Data Mis-compare encountered.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-871-003
:
Standalone Memory Test Aborted
Data Mis-compare encountered.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-877-000
:
Standalone Memory Test Aborted
BIOS: Sparing in Extended PCI reg. must be OFF. Go to setup and disable sparing.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-877-001
:
Standalone Memory Test Aborted
BIOS: Sparing in Extended PCI reg. must be OFF. Go to setup and disable sparing.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-877-002
:
Standalone Memory Test Aborted
BIOS: Sparing in Extended PCI reg. must be OFF. Go to setup and disable sparing.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-877-003
:
Standalone Memory Test Aborted
BIOS: Sparing in Extended PCI reg. must be OFF. Go to setup and disable sparing.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-878-000
:
Standalone Memory Test Aborted
Sparing feature must be turned OFF. Go to setup and turn the sparing feature OFF.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-878-001
:
Standalone Memory Test Aborted
Sparing feature must be turned OFF. Go to setup and turn the sparing feature OFF.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-878-002
:
Standalone Memory Test Aborted
Sparing feature must be turned OFF. Go to setup and turn the sparing feature OFF.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-878-003
:
Standalone Memory Test Aborted
Sparing feature must be turned OFF. Go to setup and turn the sparing feature OFF.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-885-000
:
Standalone Memory Test Aborted
Processor does not support MTRR register manipulation. Can not write to memory without cache.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-885-001
:
Standalone Memory Test Aborted
Processor does not support MTRR register manipulation. Can not write to memory without cache.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-885-002
:
Standalone Memory Test Aborted
Processor does not support MTRR register manipulation. Can not write to memory without cache.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-885-003
:
Standalone Memory Test Aborted
Processor does not support MTRR register manipulation. Can not write to memory without cache.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-886-000
:
Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-886-001
:
Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-886-002
:
Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-886-003
:
Standalone Memory Test Aborted
Memory Upper limit is less than 16 Mbytes.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Related links
-
201-899-000
:
Standalone Memory Test Aborted
Memory Diagnostics Test Aborted by user.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- Related links
-
201-899-001
:
Standalone Memory Test Aborted
Memory Diagnostics Test Aborted by user.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- Related links
-
201-899-002
:
Standalone Memory Test Aborted
Memory Diagnostics Test Aborted by user.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- Related links
-
201-899-003
:
Standalone Memory Test Aborted
Memory Diagnostics Test Aborted by user.
- Recoverable
- No
- Severity
- Warning
- Serviceable
- No
- Automatically notify support
- No
- Related links
-
201-901-000
:
Standalone Memory Test Failed
Memory Diagnostics Test Failed.
- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Replace any DIMMS(s) mentioned in error, one by one.
- Make sure that all DIMMs are enabled in the Configuration/Setup Utility program.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links
-
201-901-001
:
Standalone Memory Test Failed
Memory Diagnostics Test Failed.
- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Replace any DIMMS(s) mentioned in error, one by one.
- Make sure that all DIMMs are enabled in the Configuration/Setup Utility program.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links
-
201-901-002
:
Standalone Memory Test Failed
Memory Diagnostics Test Failed.
- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Replace any DIMMS(s) mentioned in error, one by one.
- Make sure that all DIMMs are enabled in the Configuration/Setup Utility program.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links
-
201-901-003
:
Standalone Memory Test Failed
Memory Diagnostics Test Failed.
- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Perform the actions mentioned one at a time and try the test after each action.
- If the problem remains, contact your technical-service representative.
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
- Make sure that DSA and BIOS/uEFI are at the latest level.
- Replace any DIMMS(s) mentioned in error, one by one.
- Make sure that all DIMMs are enabled in the Configuration/Setup Utility program.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links