Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 3)
This message is for the use case when an implementation has detected an
Array Failure is Predicted.
May also be shown as
806f020d0403ffff or 0x806f020d0403ffff
Alert Category
System - Predicted Failure
CIM Information
Prefix:PLAT
and ID:0168
Automatically Notify Support
Yes
User Response
- Run the hard disk drive diagnostic test on drive n.
- Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
- Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)