Numeric sensor [NumericSensorElementName] going high (upper non-recoverable)
has asserted. (Inlet Temp)
This message is for the use case when an implementation has detected an
Upper Non-recoverable sensor going high has
asserted.
May also be shown as
80010b013701ffff or 0x80010b013701ffff
Alert Category
Critical - Temperature
CIM Information
Prefix:PLAT
and ID:0498
Automatically Notify Support
No
User Response
- Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
- Check the ambient temperature. You must be operating within the specifications (see Server Features and specifications for more information).
- Make sure that the heat sink for microprocessor n.
- (Trained technician only) Replace system board.