Use this information for details about turning on the compute
node.
About this task
After you connect the compute node to power through the
IBM® Flex
System chassis,
the compute node can be started in any of the following ways:
- You can press the power button on the front of the compute node
(see Compute node controls, connectors, and LEDs) to
start the compute node. The power button works only if local power
control is enabled for the compute node. Local power control is enabled
and disabled through the CMM power command and the CMM web
interface.
Notes:
- Wait until the power LED on the compute node flashes slowly before
you press the power button. While the IMM2 in the compute node is
initializing and synchronizing with the Chassis Management Module,
the power LED flashes rapidly, and the power button on the compute
node does not respond. This process can take approximately 90 seconds
after the compute node has been installed.
- While the compute node is starting, the power LED on the front
of the compute node is lit and does not flash. See Compute node controls, connectors, and LEDs for the power LED
states.
- If a power failure occurs, the IBM Flex
System chassis
and the compute node can be configured through the CMM power command
and the CMM web interface to start automatically when power is restored.
- You can turn on the compute node through the CMM power command,
the CMM web interface, or IBM Flex
System Manager management software (if
installed).
- You can turn on the compute node through the Wake on LAN feature.
The compute node must be connected to power (the power LED is flashing
slowly) and must be communicating with the Chassis Management Module.
The operating system must support the Wake on LAN feature, and the Wake on LAN feature
must be enabled through the Chassis Management Module interface.