Use the information in this section to troubleshoot one
compute node is unable to connect to the data network (Ethernet) during
initial setup.
Complete the following steps until the problem is solved:
- Make sure that:
- The I/O module is powered on and the appropriate ports are enabled
on the I/O module.
- All cables between the I/O module and the network device (switch
or router) are properly connected and secure, and that the activity
LEDs are lit on the appropriate ports.
- From the compute node operating system, verify the network settings,
such as IP address, subnet mask (if using IPv4), DHCP settings, and
vLAN settings, to ensure that the settings match the settings of the
network device. See the documentation for the operating system for
information about checking network settings.
- From the compute node operating system, make sure that the network
device is active. See the documentation for the operating system for
information about viewing network devices.
- Make sure that the proper device drivers are installed for the
compute node Ethernet device.
- Check the IBM® support Web
site for any firmware updates that might apply to this issue. You
can view the release notes for a firmware update to determine the
issues addressed by the update.
- Remove the compute node from the chassis and check the connectors
at the back of the node for bent pins. If the pins are bent, contact
Support. See Removing a compute node from a chassis.
- Install the compute node in another compute node bay to see if
the problem persists. See Installing a compute node in a chassis.
If the problem persists, make sure that this compute node is connected
to a port that has been enabled and that the vLAN settings enable
that port to connect to the network.
- Check the IBM support Web
site for any service bulletins that are related to network connectivity.
- (Trained service technician only) Perform the following steps:
- Force the Link/duplex speed.
- Check the connectors on the I/O module to ensure that there are
no bent pins.
- Check the connectors on the chassis midplane to ensure there are
no bent pins. See the IBM Flex System Enterprise Chassis Types 8721,
8724, and 8725: Installation and Service Guide.
- Remove the I/O module and install a working I/O module in the
same I/O module bay.
- If the problem is resolved, replace the I/O module that you removed.