Complete the following steps until the problem is solved.
- Attempt to power off the compute node through the IBM® Flex
System Manager user
interface, if an IBM Flex
System Manager management
node is installed. Otherwise, attempt to power off the compute node
through the Chassis Management Module (CMM) user
interface.
- Attempt to restart the system-management processor for the compute
node. You can restart the system-management processor through the Chassis Management Module (CMM) user
interface. Click the compute node in the chassis view and then click Restart
System Mgmt Processor. After the system-management processor has
been restarted, attempt to power off the compute node from the Chassis Management Module (CMM).
- Attempt to power off the compute node by using the power button
on the front of the node.
- Attempt to reset the compute node from the Chassis Management Module (CMM) command-line
interface (CLI) by using the reset command.
- Reseat the Chassis Management Module (CMM);
then, perform steps 1-5 again.