806f090c-20010101
memory device 1 in Group 1 on Subsystem System Memory Throttled

Explanation

Memory DIMM has been throttled due to high temperature detected by the DIMM sensor.

May also be shown as 806f090c20010101 or 0x806f090c20010101

Severity

Info

Alert Category

System - Other

Serviceable

Yes

CIM Information

Prefix: PLAT and ID: 0142

SNMP Trap ID

Automatically notify Support

No

User response

Complete the following steps:

  1. Check the CMM or FSM event log for any fan or cooling related issues.
  2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
  3. Make sure that the room temperature is within operating specifications.
  4. Make sure that the DIMM baffles are in place.
  5. If the problem persists and there are no other DIMMs with the same indication, replace the DIMM.