Sensor PCH Overtemp has transitioned to non-recoverable from a less
severe state.
Explanation
A temperature has exceeded its specified threshold. The compute node
will attempt a soft shutdown.
May also be shown as
800703012d0101ff or 0x800703012d0101ff
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
CIM Information
Prefix: PLAT and ID:
0524
SNMP Trap ID
0
Automatically notify Support
No
User response
Complete the following steps until the problem is solved:
- Check the Chassis Management Module or Flex System Manager event log
for any fan- or cooling-related issues.
- Make sure that the airflow at the front and rear of the chassis is not
obstructed and that fillers are in place and correctly installed.
- Make sure that the room temperature is within operating specifications.