Sensor SEN Vol Fault has transitioned to critical from a less severe state.
Explanation
A failure has been detected in the SEN planar board.
May also be shown as
8007020219020010 or 0x8007020219020010
Severity
Error
Alert Category
Critical - Voltage
Serviceable
Yes
CIM Information
Prefix: PLAT and ID:
0522
SNMP Trap ID
1
Automatically notify Support
No
User response
Complete the following steps:
- Remove any recently installed components.
- Try to power on the compute node.
- If the compute node successfully powers on, complete the
following steps:
- Check the
ServerProven website
to make sure that recently installed components are compatible
with the compute node.
- Inspect the previously installed components for
physical damage.
- If the compute node does not successfully power on or if
this is not the first occurrence of this problem,
replace the system board.