(Trained service technician only) Use these instructions
to install the chassis shuttle in the Flex System Enterprise
Chassis.
Important: The power supplies, I/O modules, and CMM that
are installed in the shuttle connect directly to the midplane. Do
not latch these devices in the shuttle before you insert the shuttle;
the chassis is not designed for all of those devices to connect to
the midplane at the same time.
To install the chassis shuttle, complete the following
steps.
- Align the shuttle with the rear of the chassis and insert
the shuttle into the chassis.
- Push the release latches in; then, slide the shuttle into
the chassis until it locks in place.
- Tighten the captive screws that you removed earlier with
a T-15 Torx driver:
- Turn the upper-left screw 3 times.
- Turn the upper-right screw 3 times.
- Turn the lower-left screw 3 times.
- Turn the lower-right screw 3 times.
- Repeat the previous steps in
turns until the four shuttle screws secure the shuttle tightly against
the rear of the midplane.
- Install the left, right, and bottom support brackets on
the rear of the chassis, if you removed them.
After you install the shuttle, complete the following steps:
- Reinstall the components that you removed from the rear of the Flex System Enterprise
Chassis:
- Connect any cables that you disconnected from the modules in the
rear of the chassis.
- Connect the chassis to power (see Connecting the chassis to power).
- Restart any compute nodes that
you shut down. See the documentation that comes with each compute node for
detailed instructions.
- Restart the management node, if one is installed. See the Flex System Manager Installation
and Service Guide for instructions.