Use these instructions to install a 2-bay compute node in
the Flex System Enterprise
Chassis.
You can install a compute node while
the chassis is powered on.
Before you install a
compute node into
the chassis, complete the following steps:
- Verify that the compute node is
compatible with the chassis. See the Lenovo ServerProven website.
- Read the instructions that come with the compute node.
- Make sure that you have installed any optional hardware devices
in the compute node.
Note: This procedure assumes that you are replacing an existing
compute node in
the same node bays. If you are installing a new
compute node, see
Installing components.
To install a 2-bay compute node, complete
the following steps.
- Open both release handles (rotate the left handle to the
left and rotate the right handle to the right).
- Slide the compute node into
the node bays until it is seated.
- Close both release handles.
After you install the
compute node, make
a note of the
compute node identification
information on the labels that come with the
Flex System Enterprise
Chassis.
Place a label on the node label tab and on the adjacent chassis label
plate, to the left of the
compute node. See
User labels for more information.
Important: Do not place the label on the compute node or
in any way block the ventilation holes on the chassis.