Removing a Flex System Manager management node

Use these instructions to remove a Flex System Manager management node from the Flex System Enterprise Chassis.

Note: These instructions assume that the chassis is powered on.
Before you remove an Flex System Manager management node, complete the following steps:
  1. If the management node that is currently installed in the chassis is functioning, back up the management node image before you replace the management node.

    See the Flex System Manager Installation and Service Guide for instructions.

  2. Shut down the management node.

    See the Flex System Manager Installation and Service Guide for instructions.

  3. Disconnect all cables from the management node.

To remove the management node, complete the following steps.


Graphic illustrating the removal of a Flex System Manager from the chassis

  1. Open the release handle (rotate the handle to the left) to disengage the management node from the chassis.
  2. Slide the management node out of the chassis and place it on a flat, static-protective surface.