You can install up to seven 2-bay compute nodes in
the chassis. A 2-bay device occupies two adjacent node bays (horizontally)
in the chassis.
Before you install a
compute node in
the
Flex System Enterprise
Chassis,
complete the following steps:
- Verify that the compute node is
compatible with the chassis. See the Lenovo ServerProven website.
- Make sure that enough power supplies and fan modules are installed
in the chassis to support the compute node. See Installing components to determine
the number of power supplies and 80 mm fan modules that are required
and where they should be installed in your chassis configuration.
- Read the instructions that come with the compute node.
- Make sure that you have installed any optional hardware devices
in the compute node.
- Select the bays for the compute node. Two
adjacent bays are required.
- Remove the fillers and the chassis shelf from the selected bays,
if they are installed. See Removing a chassis shelf for instructions.
To install a 2-bay compute node, complete
the following steps.
- Open both release handles (rotate the left handle to the
left and rotate the right handle to the right).
- Slide the compute node into
the node bays until it is seated.
- Close both release handles.
After you install the
compute node, make
a note of the
compute node identification
information on one of the labels that come with the
Flex System Enterprise
Chassis.
Place a label on the node label tab and on the adjacent chassis label
plate, to the left of the
compute node. See
User labels for more information.
Important: Do not place the label on the compute node or
in any way block the ventilation holes on the chassis.