You can install up to fourteen 1-bay compute nodes in
the Flex System Enterprise
Chassis.
Compute nodes are installed in the front of the Flex System Enterprise
Chassis.
Before you install a
compute node in
the
Flex System Enterprise
Chassis,
complete the following steps:
- Verify that the compute node is
compatible with the chassis. See the Lenovo ServerProven website.
- Make sure that enough power supplies and fan modules are installed
in the chassis to support the compute node. See Installing components to determine
the number of power supplies and 80 mm fan modules that are required
and where they should be installed in your chassis configuration.
- Read the instructions that come with the compute node.
- Make sure that you have installed any optional hardware devices
in the compute node.
- Select the bay for the compute node.
To install a 1-bay compute node, complete
the following steps.
- Remove the node bay filler, if one is installed. Push the
filler release tab to the right; then, grasp the filler by the slot
and pull it out of the bay.
- Open the release handle (rotate the handle to the left).
- Slide the compute node into
the node bay until it is seated.
- Close the release handle (rotate the handle to the right).
After you install the
compute node, make
a note of the
compute node identification
information on one of the labels that come with the
Flex System Enterprise
Chassis.
Place a label on the node label tab and on the adjacent chassis label
plate, to the right or left of the
compute node (depending
on the bay in which the
compute node is
installed). See
User labels for
more information.
Important: Do not place the label on
the compute node or
in any way block the ventilation holes on the chassis.