System-management processor firmware on [arg1] does not support the cipher suite level selected on the Chassis Management Module.
The system-management processor for the specified node does not support the
setting of the cipher suite level that was selected on the Chassis Management
Module. The system-management processor's web server might allow connections
using cipher suites below the desired minimum level. Also, users might not be
able to log into the node system-management processor.
Alert Category
Nodes (Warning)
Chassis LED that is Lit
None
CIM Information
Prefix:CMM
and ID:0716
Automatically Notify Support
No
User Response
Ensure that the node system-management processor has the correct level of
firmware to support the security functions enabled on the Chassis Management
Module. If you cannot log onto the node system-management processor, you might
need to temporarily set the cipher suite level to the "legacy" setting on the
CMM.