System-management processor firmware on [arg1] does not support the certificate cryptography algorithm configured on the CMM.
The system-management processor for the specified node does not support the certificate cryptography algorithm
configured at the management module. The service processor may not be able to utilize the certificates it
has been provisioned with. System-management functions may not work correctly, including web interface and user login.
Alert Category
Nodes (Warning)
Chassis LED that is Lit
None
CIM Information
Prefix:CMM
and ID:0753
Automatically Notify Support
No
User Response
Ensure that the node system-management processor has the correct level of firmware to support the security functions
enabled on the Chassis Management Module. If you cannot log onto the node system-management processor, you might need
to temporarily set the certificate cryptography algorithm to the "RSA2048-SHA1" setting on the CMM