35010001 : New Certificate Authority established.

New Certificate Authority established.

A new digital certificate has been established for the chassis Certificate Authority. Logon failures and communication failures might occur if the certificate is not distributed to devices that use the chassis Certificate Authority to authenticate the Chassis Management Module (CMM) or system-management processors. To distribute the certificate to the Flex System Manager management software, configure the Flex System Manager management software to manage the chassis after the new certificate has been established. To distribute the certificate to an external device such as an LDAP server, export the certificate from the CMM, and then import the certificate into the external device.

Severity

Informational

Alert Category

Chassis/System Management (Informational)

Log Source

SERVPROC

Serviceable

No

Recoverable

No

Chassis LED that is Lit

None

CIM Information

Prefix:CMM

and ID:0401

SNMP Trap ID

mmTrapChassisS

Automatically Notify Support

No

User Response

Information only; no action is required.