System firmware for [arg1] does not support Fabric Manager.
The system firmware for the node does not support Fabric Manager . The
Fabric Manager configuration cannot be applied to the specified node. The node can not
be powered on because the Chassis Management Module will not grant permission to
power on to the system-managment processor on the node.
Alert Category
Nodes (Warning)
Chassis LED that is Lit
Chassis Check Log
CIM Information
Prefix:CMM
and ID:1015
Automatically Notify Support
No
User Response
If the node supports Fabric Manager, update the node system firmware with the latest level
of firmware that supports Fabric Manager. If the node does not support Fabric Manager, then set the
Fabric Manager mode off
for this node. The system-management processor on the node must be restarted to disable
Fabric Manager after Fabric Manager support has been disabled by the user.