0F00D007 : System firmware for [arg1] does not support Fabric Manager.

System firmware for [arg1] does not support Fabric Manager.

Severity

Warning

Alert Category

Nodes (Warning)

Log Source

Node_07

Serviceable

Yes

Recoverable

Yes

Chassis LED that is Lit

Chassis Check Log

CIM Information

Prefix:CMM

and ID:1015

SNMP Trap ID

mmTrapBladeN

Automatically Notify Support

No

User Response

If the node supports Fabric Manager, update the node system firmware with the latest level of firmware that supports Fabric Manager. If the node does not support Fabric Manager, then set the Fabric Manager mode off for this node. The system-management processor on the node must be restarted to disable Fabric Manager after Fabric Manager support has been disabled by the user.