0F00C007 : Node [arg1] not allowed to power on; constrained by power budget.

Node [arg1] not allowed to power on; constrained by power budget.

While the specified node is being powered on, the Chassis Management Module has detected that there is no longer enough capacity in the power budget to allow the node to continue powering on.

Severity

Warning

Alert Category

Nodes (Warning)

Log Source

Node_07

Serviceable

Yes

Recoverable

Yes

Chassis LED that is Lit

Chassis Check Log

CIM Information

Prefix:CMM

and ID:0822

SNMP Trap ID

mmTrapBladeN

Automatically Notify Support

No

User Response

Complete the following steps until the problem is solved:
  1. Select a different power management policy to increase the power budget.
  2. Install additional power supplies to increase the power capacity.
  3. Individually remove lower-priority devices from the chassis until the power budget is sufficient.