Chassis temperature device is unavailable.
The chassis temperature is unavailable or unreadable from the rear LED card.
The cooling capacity of the chassis has been set to the maximum,
and the fan modules are running at full speed.
Alert Category
Chassis/System Management (Warning)
Chassis LED that is Lit
Chassis Check Log
CIM Information
Prefix:CMM
and ID:0158
SNMP Trap ID
mmTrapChassisN
Automatically Notify Support
No
User Response
Check the Chassis Management Module event log for communication failures for multiple components,
such as I/O modules, fan modules, and power supplies.
If there are communication failures for multiple components,
restart the Chassis Management Module.
If there are no other communication failures, replace the rear LED card.