Standby Chassis Management Module failure on the system management bus. Check devices.
The Chassis Management Module (CMM) has detected a failure
on the systems-management bus.
A failover was initiated, and the primary CMM is now the standby CMM.
Alert Category
Chassis/System Management (Critical)
Chassis LED that is Lit
Chassis Fault
CIM Information
Prefix:CMM
and ID:0278
SNMP Trap ID
mmTrapChassisC
Automatically Notify Support
No
User Response
Use one of the following procedures:
- If active problems are reported in the Chassis Management Module log, solve them.
- If no active bus problems are reported in the log,
during scheduled maintenance, swap the physical locations of the
primary CMM and the standby CMM.
If the problems follow the CMM, replace the CMM.
Otherwise, replace the device that is reported in the log.