Ethernet [[arg1]] interface is down for the standby Chassis Management Module.
The Chassis Management Module external Ethernet interface is down for the standby Chassis Management Module.
Devices internal to the chassis on the management network,
such as system-management processors and the
Flex System Manager management module, will also lose
network connectivity.
Alert Category
Chassis/System Management (Informational)
Chassis LED that is Lit
None
CIM Information
Prefix:CMM
and ID:0656
SNMP Trap ID
mmTrapChassisS
Automatically Notify Support
No
User Response
Complete the following steps until the problem is solved:
- Make sure that the external Ethernet cable is connected at both ends.
- Make sure that the cable is working:
- Swap both ends of the cable.
- Make sure that the link LED on the RJ-45 connector is lit
on the Chassis Management Module (CMM)
and on the network device to which the CMM is attached.
- Make sure that the network switch has power.
- Make sure that the network infrastructure is operational.