4000001c-00000000
Watchdog [arg1] Screen Capture Occurred.

Explanation

An operating-system error has occurred, and the screen capture was successful.

May also be shown as 4000001c00000000 or 0x4000001c00000000

Severity

Info

Alert Category

System - other

Serviceable

No

CIM Information

Prefix: IMM and ID: 0028

SNMP Trap ID

22

Automatically notify Support

No

User response

If there was no operating-system error, complete the following steps until the problem is solved:
  1. Reconfigure the watchdog timer to a higher value.
  2. Make sure that the IMM Ethernet-over-USB interface is enabled.
  3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
  4. Disable the watchdog.
If there was an operating-system error, check the integrity of the installed operating system.

Related Links