Use this information to remove an adapter-retention assembly.
The adapter-retention assembly is in the lower compute node.
Before you remove an adapter-retention assembly, complete
the following steps:
- Read Safety and Installation guidelines.
- If the Flex System x222 Compute Node is
installed in a chassis, remove it (see Removing a compute node from a chassis for
instructions).
- Carefully lay the compute node on a flat, static-protective
surface, orienting the compute node with the bezel pointing toward
the left.
The adapter-retention assembly consists of multiple separate
parts. You can replace only the parts that you choose and save the
unused parts for future use.
To remove an adapter-retention assembly, complete
the following steps.
- Remove the upper compute node (see Removing the upper compute node).
- Using a T10 Torx screwdriver, remove the screws that secure
each part of the adapter-retention assembly to the compute node.
- Lift each part of the adapter-retention assembly from the
lower system board.
- Carefully return the compute node to the bottom-side-down
orientation.
If you are instructed to return an adapter-retention assembly,
follow all packaging instructions, and use any packaging materials
for shipping that are supplied to you.