Use this information to remove an I/O expansion adapter
from the lower compute node. Expansion adapters can not be installed
in the upper compute node; the upper and lower compute nodes share
the I/O expansion adapter in the lower compute node.
Before you remove an I/O expansion adapter, complete the following
steps:
- Read Safety and Installation guidelines.
- If the Flex System x222 Compute Node is
installed in a chassis, remove it (see Removing a compute node from a chassis for
instructions).
- Carefully lay the compute node on a flat, static-protective
surface, orienting the compute node with the bezel pointing toward
the left.
To remove an I/O expansion adapter, complete the following
steps.
- Remove the upper compute node (see Removing the upper compute node).
- Locate the I/O expansion adapter in the lower compute node
(see System-board layouts).
- Loosen the captive adapter-retention thumb screws.
You can loosen these screws by hand or by using a P1 Phillips screwdriver.
- Lift the I/O expansion adapter from the connector and remove
the I/O expansion adapter from the compute node. You might find it
helpful to rock the adapter back and forth to disengage the adapter.
If you are instructed to return an I/O expansion adapter,
follow all packaging instructions, and use any packaging materials
for shipping that are supplied to you.