Use this information to install an adapter-retention assembly
in the lower compute node.
Before you install an adapter-retention assembly, complete
the following steps:
- Read Safety and Installation guidelines.
- If the Flex System x222 Compute Node is
installed in a chassis, remove it (see Removing a compute node from a chassis for
instructions).
- Carefully lay the compute node on a flat, static-protective
surface, orienting the compute node with the bezel pointing toward
the left.
The adapter-retention assembly consists of multiple separate
parts. You can replace only the parts that you choose and save the
unused parts for future use.
To install an adapter-retention assembly, complete the
following steps.
- Remove the upper compute node (see Removing the upper compute node).
- Carefully place the lower compute node on its side with
the front handle side up.
- Align each part of the adapter-retention assembly on the
lower system board.
- Using a T10 Torx screwdriver, install the screws that secure
each part of the adapter-retention assembly.
- Carefully return the compute node to the bottom-side-down
orientation.
- Install the I/O expansion adapters, if you removed them
(see Installing an I/O expansion adapter).
After you install an adapter-retention assembly, complete
the following steps:
- Install the upper compute node (see Installing the upper compute node for instructions).
- Install the Flex System x222 Compute Node into
the chassis (see Installing a compute node in a chassis for
instructions).