Use this information to install a simple-swap
hard disk drive. The Flex System x222 Compute Node can
use 2.5-inch simple-swap hard disk drives of either the standard or
solid-state drive (SSD) design. Simple-swap hard disk drives can be
installed in both the upper and lower compute nodes.
Important: Simple-swap hard disk drives
are not hot-swap devices and must be removed or installed with the
compute node turned off. For information about installing optional
1.8-inch hot-swap solid-state drives, see
Installing a solid state drive.
Before
you remove a simple-swap hard disk drive, complete the following steps.
- Read Safety and Installation guidelines.
- If the compute node where you are installing the simple-swap hard
disk drive is operating, shut down its operating system.
- Press the power button to turn off the compute node where you
are installing the simple-swap hard disk drive (see Turning off a compute node for more information).
The upper and lower compute nodes each have one SATA hard
disk drive bay for installing a simple-swap hard disk drive.
Note:
- You can install multiple solid state drives (SSDs) in an upper
or lower compute node if an optional solid state drive mounting sleeve
is installed in the upper or lower compute node.
- Each compute node can support RAID level-0 (striping), when a
single hard disk drive is installed in an upper or lower compute node,
or RAID level-1 (mirroring), when two 1.8-inch solid-state drives
are installed in an upper or lower compute node. See Configuring a RAID array for information
about RAID configuration.
To install a simple-swap hard disk drive
or hard disk drive bay filler, complete the following steps.
- Identify the hard disk drive bay in which you plan to install
the simple-swap hard disk drive.
- If a hard disk drive bay filler is installed, remove it
from the compute node by pressing the release latches toward the center
of the filler and sliding the filler away from the compute node.
- Touch the static-protective package that contains the hard
disk drive to any unpainted metal surface on the Flex System chassis
or any unpainted metal surface on any other grounded rack component;
then, remove the hard disk drive from the package.
Note: The hard disk drives in the upper and lower compute nodes
are installed in opposite orientation to each other.
- Orient the hard disk drive so that the beveled edge of
the drive bezel is toward the center of the Flex System x222 Compute Node.
- Slide the hard disk drive into the bay until it is firmly
seated in the connector. The release latches will click when the drive
is fully seated.