Use this information to configure a RAID array on your compute node.
RAID level-0 (striping) can be configured on a compute node with a single hard disk drive installed. A minimum of two disk drives must be installed to implement and manage RAID level-1 (mirroring) arrays in operating systems that are listed on the ServerProven list at the Lenovo ServerProven website. Each drive must have the same type of interface and speed and if drives of differing capacity are used, the controller will treat them all as if they have the capacity of the smallest drive. If you are configuring RAID for a compute node with multiple drives, both drives must be included in the RAID array.
The compute node comes with an integrated ServeRAID C100 controller integrated on the system board: no additional hardware is required. The ServeRAID C100 controls all devices that are connected to the system board SATA ports, with RAID functions disabled by default.
Important: You must create the software RAID array before you install the operating system on the compute node.
To create a software RAID array using the integrated ServeRAID C100 controller, complete the following steps: