Use the information in this section to troubleshoot a compute
node that does not power off.
- Complete the following steps until the problem is solved.
- Attempt to power off the compute node through the Flex System Manager user
interface, if an Flex System Manager management
node is installed. Otherwise, attempt to power off the compute node
through the CMM user
interface.
- Attempt to restart the system-management processor for the compute
node. You can restart the system-management processor through the CMM user
interface. Click the compute node in the chassis view and then click Restart
System Mgmt Processor. After the system-management processor has
been restarted, attempt to power off the compute node from the CMM.
- Attempt to power off the compute node by using the power button
on the front of the node.
- Attempt to reset the compute node from the CMM command-line
interface (CLI) by using the reset command.
- Reseat the CMM;
then, perform steps 1-5 again.