806f020d-0401ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 1)

Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 1)

Severity

Warning

Alert Category

System - Predicted Failure

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0168

SNMP Trap ID

27

Automatically Notify Support

Yes

User Response

  1. Run the hard disk drive diagnostic test on drive n.
  2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
  3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)