806f0207-0301ffff : [ProcessorElementName] has Failed with FRB1/BIST condition. (CPU 1)

[ProcessorElementName] has Failed with FRB1/BIST condition. (CPU 1)

Severity

Error

Alert Category

Critical - CPU

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0044

SNMP Trap ID

40

Automatically Notify Support

Yes

User Response

  1. Update the latest level of system firmware and device drivers are installed for all adapters and standard devices, such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
  2. Run the DSA program.
  3. Reseat the adapter.
  4. Replace the adapter.
  5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
  6. (Trained technician only) Replace the system board.