If you omit any optional parameter, the default value is
used.
To update the UUID, in the ASU command-line interface,
enter the following command:
asu set SYSTEM_PROD_DATA.SysInfoUUID uuid --host ipaddress [--user userid][--password password]
where:
- uuid
- is the user-assigned hexadecimal value, up to 16 bytes, that identifies
the compute node.
- ipaddress
- is the external LAN IP address of the IMM2.
- userid
- is the IMM2 account name (1 of 12 accounts). The default is USERID.
- password
- is the IMM2 account password (1 of 12 accounts). The default is
PASSW0RD (with a zero, not the letter O).
To update the DMI/SMBIOS data, complete the following
steps:
- In the ASU command-line interface, enter the following
command:
asu set SYSTEM_PROD_DATA.SysInfoProdName xxxxyyy --host ipaddress [--user userid][--password password]
where:
- xxxx
- is the 4-digit machine type of the compute node.
- yyy
- is the 3-digit model number of the compute node.
- ipaddress
- is the external LAN IP address of the IMM2.
- userid
- is the IMM2 account name (1 of 12 accounts). The default is USERID.
- password
- is the IMM2 account password (1 or 12 accounts). The default is
PASSW0RD (with a zero, not the letter O).
- Enter the following command:
asu set SYSTEM_PROD_DATA.SysInfoSerialNum zzzzzzz --host ipaddress [--user userid][--password password]
where zzzzzzz is
the 7-character serial number of the compute node.
- Enter the following command:
asu set SYSTEM_PROD_DATA.SysEncloseAssetTagaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa --host ipaddress [--user userid][--password password]
where aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is
the 33-character asset tag number of the compute node.