This access method uses the IPMI/KCS interface. The IPMI
driver must be installed; with some operating systems, the IPMI driver
is installed by default. The ASU provides the corresponding mapping
layer.
To update the UUID, in the ASU command-line interface,
enter the following command:
asu set SYSTEM_PROD_DATA.SysInfoUUID uuid --kcs
where uuid is
the user-assigned hexadecimal value, up to 16 bytes, that identifies
the compute node.
The --kcs parameter indicates that a kcs channel
is used to communicate with the IMM.
To update the DMI/SMBIOS
data, complete the following steps:
- In the ASU command-line interface, enter the following
command:
asu set SYSTEM_PROD_DATA.SysInfoProdName xxxxyyy --kcs
where:
- xxxx
- is the 4-digit machine type of the compute node.
- yyy
- is the 3-digit model number of the compute node.
- Enter the following command:
asu set SYSTEM_PROD_DATA.SysInfoSerialNum zzzzzzz --kcs
where zzzzzzz is
the 7-character serial number of the compute node.
- Enter the following command:
asu set SYSTEM_PROD_DATA.SysEncloseAssetTagaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa --kcs
where aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is
the 33-character asset tag number of the compute node.