Light path diagnostics LEDs

Use this information to diagnose possible errors that are indicated by the light path diagnostics LEDs.

The following table describes the LEDs on the light path diagnostics panel and the light path diagnostics LEDs on the system board. See Viewing the light path diagnostics LEDs for information about lighting the LEDs.

Lit light path diagnostics LED Description
None The compute node is not sufficiently charged to display the LEDs on the system board.
BMC error Future use only.
Battery error The system CMOS battery is not installed or is not working.
DC power error Future use only.
DIMM x error A memory error occurred.
I/O expansion unit Future use only.
Light path diagnostics The power source for the light path diagnostics LEDs is charged.
Light path diagnostics only No errors have occurred.
Memory A memory error has occurred.
Microprocessor x error The IMM2 lights this LED when a microprocessor has failed or overheated or the start microprocessor (CPU 1) is missing. The fault LED on the front panel is also lit.
Mismatch The microprocessors are mismatched. If the MEM LED is also lit, the DIMMs are mismatched.
NMI The system board has failed.
System board The system board has failed.
Temperature The system temperature has exceeded a threshold level.
LSI SAS Error A SAS error has occurred.