S.2018001 : [S.2018001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %. The Vendor ID for the device is % and the Device ID is %.

[S.2018001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %. The Vendor ID for the device is % and the Device ID is %.

Severity

Error

User Response

Complete the following steps:
  1. If this compute node and/or any attached cables were recently installed, moved, serviced or upgraded:
    1. Reseat the adapter and any attached cables.
    2. Reload the device driver.
    3. If device is not recognized, reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed Selection, or the ASU Utility.
  2. Check the IBM support site for an applicable device driver, firmware update, or other information that applies to this error. Load the new device driver and install any required firmware updates.
  3. If the problem persists, remove the adapter. If the system reboots successfully without the adapter, replace that adapter.
  4. Replace the processor.