Sensor CPU 1 Overtemp has gone to Nonrecoverable state from a
less severe state.
Alert Category
Critical - Temperature
CIM Information
Prefix:PLAT
and ID:0524
Automatically Notify Support
No
User Response
Complete the following steps until the problem is solved:
- Check the Chassis Management Module or Flex System Manager event log
for any fan- or cooling-related issues.
- Make sure that the airflow at the front and rear of the chassis is not
obstructed and that fillers are in place and correctly installed.
- Make sure that the room temperature is within operating specifications.
- Make sure that the microprocessor 1 heat sink is securely installed.
- Make sure that the microprocessor 1 heat sink is installed correctly
and the thermal material is correctly applied.
- Replace microprocessor 1.