80070217-2c01ffff : Sensor Mezz Exp 1 Fault has transitioned to critical from a less severe state.

Sensor Mezz Exp 1 Fault has transitioned to critical from a less severe state.

Severity

Error

Alert Category

Critical - Other

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0522

SNMP Trap ID

50

Automatically Notify Support

No

User Response

Complete the following steps:
  1. Remove any recently installed components from the PCI expansion unit.
  2. Try to power on the chassis.
    • If the chassis successfully powers on, complete the following steps:
      1. Check the ServerProven website to make sure that recently installed components are compatible with the chassis.
      2. Inspect the previously installed components for physical damage.
    • If the chassis does not successfully power on or if this is not the first occurrence of this problem, replace the PCI expansion unit.